Hear From Our Experts

Single-Use Assembly Specification: What to Define First

A single-use assembly specification is a design brief, not an order form. The process, duty and interface detail a supplier needs before drawing.

The slowest part of getting a custom fluid path built is almost never manufacturing. It is the loop of drawing, comment and revision that happens because the initial brief described components instead of describing the process. A single-use assembly specification is a design brief, and it is worth writing as one.

Every supplier page on this subject describes the same sequence: consultation, component selection, drawing, approval, build. That is accurate and it is also written from the supplier's side of the table. What is harder to find is the other half, which is what the engineer needs to have decided before that first conversation is useful.

This is that half. It covers what a specification has to fix, what it can safely leave open, and where ambiguity reliably turns into a second revision.

What a Single-Use Assembly Specification Is For

The specification exists to transfer process knowledge that only you have. A supplier can select tubing, size a connector, choose a filter format and lay out a manifold. They cannot know that the transfer runs at four in the morning with one operator, that the bag hangs on a frame two metres from the skid, or that the step before this one leaves the line warm.

Anything that is a consequence of your process rather than a property of the components is what the document has to carry. Everything else is better left as a requirement than a part number, because assemblies designed around a specific process tend to arrive closer to right when the brief states the duty and lets the engineering follow.

A good test: if a line in your specification could be written by somebody who has never seen your facility, it probably does not need to be in there. If it could only be written by somebody who has, it definitely does.

Start With the Process, Not the Parts

Begin with the step the assembly serves and the operations it performs in order. Buffer transfer from a 200 L bag into a hold vessel, with an inline sample before and after, is a more useful opening statement than a list of tubing sizes. It tells the designer what has to be possible and lets them work backwards to the components.

Say which unit operation it belongs to, upstream or downstream, and name it: media transfer, harvest collection, viral inactivation hold, depth filtration, chromatography feed, final fill. Each of those carries assumptions about sterility boundaries, hold times and what happens either side.

State what the assembly connects at each end, physically. An assembly that terminates at a bag, a stainless vessel with a ferrule, a filter housing and a pump head is four different interface problems, and interfaces are where most revisions originate. If you are unsure of the vocabulary here, the anatomy of a single-use fluid path is a reasonable starting point before writing anything down.

Fluid and Duty Data the Supplier Actually Needs

The numbers that change component selection are a short list, and most briefs are missing at least two of them.

  • Fluid. What it is, roughly what it contains, and whether it is shear-sensitive, viscous, particulate-laden or aggressive to elastomers.
  • Volume and flow. Batch volume, the flow rate you expect to run at, and the maximum you might run at during a recovery or flush.
  • Pressure. Normal operating pressure and the highest credible pressure, including whatever a blocked filter or a closed valve could generate.
  • Temperature. Both the process temperature and any excursion, including cold storage and warm buffer.
  • Duration. How long fluid sits in the path, which drives contact-time and extractables questions.
  • Cycles. Single use in one shift, or repeated cycling across a campaign.

Pressure is the one most often understated. A path specified for the pressure it normally sees will be built for that, and the failure will occur during the abnormal event rather than during the normal one. Give the credible maximum and say what generates it.

Where the assembly includes an actuated element, say how it will be driven. A line that a control system has to modulate needs a valve the control system can command to a position, which is a different component and a different cable route from a valve an operator sets by hand.

Interfaces: Where the Assembly Meets Everything Else

List every termination and describe it as it physically exists, not as it is named on a drawing. For each: the fitting type and size, whether it is made or broken by an operator, whether it must be made aseptically, and what it mates to.

Include the physical layout as well as the connection type. Leg lengths, the distance between fixed points, the height difference between a bag and a skid and the route a line has to take around a frame all determine whether an assembly that is correct on paper can actually be installed. A tubing run that is 300 mm short is a rebuild, not an adjustment.

Say which connections are permanent. Any joint that never has to be broken can be built in at manufacture instead of assembled on the floor, and where the geometry justifies it, connectors molded in-house rather than bought in can replace an assembled fitting entirely. Each one removed is one fewer joint to qualify and one fewer thing to leak.

Sterilisation, Documentation and Testing

State the sterilisation method and constraints, because it affects material selection rather than just packaging. Gamma irradiation is the usual route for pre-sterilised assemblies and it changes polymer properties; if there is a dose range your quality group requires, name it in the brief rather than leaving it to be discovered at qualification.

Set out the documentation you need alongside the hardware: material certification, traceability records and whatever your validation package expects. This is cheaper to agree before the first build than to retrofit afterwards, and it is a common cause of a technically correct assembly being unusable on a GMP line.

Ask what testing is performed before shipment and what evidence comes with it. Every assembly we build is inspected before it leaves our facility in Ireland. The question worth asking any supplier, ourselves included, is what that inspection covers and what record you receive of it.

How MonoBiologics Builds Single-Use Assemblies

At MonoBiologics, each assembly is designed around the customer's process and built by our own team in Ireland, which is why a clear brief makes such a difference to the first drawing. Because we also supply ARTēVA™ single-use pinch valves and PIXER® single-use diaphragm pumps, valves and pumps can be designed into the assembly from the start rather than added around it afterwards.

A Specification Checklist

Before sending anything, confirm the brief answers all of these:

  • Which unit operation the assembly serves, and what it does in order
  • Fluid, batch volume, flow rate, operating and maximum pressure, temperature range
  • Contact duration and number of use cycles
  • Every termination: fitting type, size, what it mates to, who connects it
  • Which connections are permanent and which are made in the field
  • Aseptic connection points and where the sterile boundary sits
  • Physical layout: leg lengths, fixed points, height differences, routing constraints
  • Sterilisation method and any dose or material constraints
  • Instrumentation and any element the control system has to drive
  • Documentation, traceability and testing evidence required
  • Quantity, first-article expectations and the timeline you are working to

Two further points are worth stating explicitly even though they are not technical. Say what you are uncertain about, so the designer proposes rather than guesses. And say what is fixed by something outside your control, such as an existing skid fitting, so nobody spends a revision improving a constraint you cannot change.

Frequently Asked Questions

What information does a supplier need to design a single-use assembly?

The process step and what the assembly does in order, the fluid and its properties, batch volume, flow rate, operating and maximum pressure, temperature range, contact duration, every termination and what it mates to, the physical layout including leg lengths, the sterilisation method, and the documentation your validation package requires.

Should a specification name specific components or state requirements?

State requirements wherever you can. Anything that is a consequence of your process, such as layout, duty and interfaces, only you can supply. Component selection is what the supplier is for, and briefs written as part numbers tend to lock in choices made for a previous process rather than this one. Name a component only where it is genuinely fixed.

Why do custom assembly designs need several revisions?

Most revisions come from interfaces and physical layout rather than from fluid data. A drawing that is correct in schematic terms can still be impossible to install if leg lengths, fixed points and height differences were not stated. Describing every termination as it physically exists, and giving real dimensions, removes the majority of that iteration.

What should be specified about sterilisation?

The method, and any constraint attached to it. Gamma irradiation is the usual route for pre-sterilised assemblies and it affects polymer properties, so if your quality group requires a particular dose range, state it in the brief. Leaving it implicit means it is discovered during qualification, which is the most expensive point at which to find it.

A specification that fixes the process, the duty and the interfaces, and leaves component selection open, will generally produce a workable drawing on the first pass. The parts of it only you can write are the parts worth spending time on.

If you have a draft brief and want a design review before it goes any further, you can send a draft specification to our engineering team.

Hear From Our Experts

Your guide to single-use success

Explore insightful articles and tips.